Skip to Content
Kenall Manufacturing - Homepage
Main Content

MPWUD-TW

MedMaster

MPWUD-TW Main Image
MPWUD-TW Main Image
Model #: MPWUD-TW
Features:
  • 48" surface wall mount luminaire with bi-directional illumination for ambient/reading functionality
  • High-output, high-CRI white LED lamp sources with 2700K-6500K white tuning capability
  • Standard antimicrobial finish
Application(s):Patient Rooms
Lens Type(s):Clear Prismatic Polycarbonate
Frost High Impact Acrylic
Lamp Type(s):LED
Size(s):24"L
36"L
48"L
Listings:  
Specifications are subject to change without notice. Please consult your Kenall Customer Service for help with special requests at (800) 4 Kenall.

Technical Specifications

Baseplate16-gauge CRS baseplate provided with four-point (24" housing) or six-point (36" housing) mounting holes and one wireway hole. TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%.
Driver/Controls120-277VAC, 50/60Hz electrical input (PF ≥ 0.9, THD < 20%). Minimum 85% electrical efficiency. Serviceable, constant-current multi-channel programmable driver with dual analog (0-10V) control inputs for intensity and CCT. Linear intensity and CCT adjustment profiles with 1-100% range and dim-to-dark capabilities on intensity. Optional DALI driver with 1-100% range and dim-todark intensity dimming with linear intensity and CCT adjustment profiles.
HousingMarine grade aluminum body with die-cast end caps. Housing attached to mounted baseplate. Housing secured with countersunk fasteners. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. Matte white antimicrobial finish standard on exposed surfaces of installed luminaire.
InstallationStandard four-point (24" housing) or six-point (36" & 48" housing) mounting.
LED ModuleServiceable tunable-white, mid-power LED array provides 2700K through 6500K CCT range with a two-point path. Minimum 82 CRI standard (R9 >20) with optional minimum 90 CRI (R9 >50).
LensUV-stabilized, high impact resistant, extruded linear DR/acrylic (50/50 blend). Smooth exterior, fluted interior. Nominal thickness .125". Lens securely positioned in body channels.
ListingsUL and CUL Listed for Damp Location. Certified by independent lab to meet OSHPD seismic loading standard. Pre-approved by OSHPD for installation in California healthcare facilities.
OpticsExtruded high-efficiency diffused, impact-resistant acrylic lens.
PatentU.S.Patent No. D562,767 on low Voltage Controller (LVC) option.

This product is able to comply with the latest domestic preference legislation, such as the Buy American Act (BAA), Trade Agreement Act (TAA), Build America, Buy America Act (BABA), and others.

Downloads

Product Documentation

Installation Files

Photometry (IES)

REVIT Files

top