Doorframe | 20-gauge type 304 stainless steel (#4 finish-post fabrication). One-piece 60° beveled perimeter construction. Continuous angle lens retention system. Mechanical guide for doorframe fastener alignment. Doorframe secured to housing with stainless steel aircraft cables and captive flush mounted Phillips head stainless steel fasteners (8) for 2×2, (12) for 2×4.
|
---|
Doorframe Gasket | One-piece closed cell extruded Nitrile gasket seals doorframe to housing and ceiling structure. |
---|
Electrical |
(Single- and Dual-Mode ICT) Serviceable mid-power white and 405nm Indigo LED array. Available 3200K, 3700K and 4300K color temperatures with 3-step MacAdam variation allowance. Minimum 82 CRI standard. 120-277VAC and 347VAC electrical input with serviceable high power factor electronic, constant-current drivers (<10% THD, >0.90 PF). Minimum 85% driver efficiency. Standard 0-10V dimming with 1-100% range and dim-to-dark capabilities. 495μA maximum source current. Single-Mode ICT provides a single, white disinfection operational mode. Dual-Mode ICT provides two operational modes based on room occupancy. White Disinfection Mode is a white LED array for ambient lighting plus a simultaneous low-power 405nm LED array for low-level, continuous and safe environmental disinfection. Indigo Disinfection Mode is a higher-level 405nm array for continuous safe environmental disinfection during periods of room vacancy. The operational mode is determined via internal low-voltage device based upon the input signal provided by an external control device/system. Luminaire dimming is overridden in this operational state. Refer to the Kenall Dual-Mode ICT Control Application Guide for further description.
|
---|
Housing | Standard 24-gauge (optional 20-gauge) cold rolled steel, hole-free, one-piece, seam-welded construction. 18-gauge housing flange with mitered and welded corners. White TGIC polyester powder coat finish – 5-step pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. |
---|
Installation | Non-IC recessed ceiling mounting into grid and flange application types. Flange installation utilizes included adjustable swing-out mounting brackets. Grid installation suitable for 1" and 1.5" T-bar ceilings. Housing is universal between grid and flange-style mounting types. See Options for continuous row mounting and install frames. |
---|
Listings | Luminaire is certified to UL standards by Intertek Testing Laboratories for Wet Location. Certified IP66 per IEC 60598. NSF2 Splash/Non-Food Zone. CCEA Approved. Suitable for biosafety labs rated BSL 3 and 4. Optional NSF Protocol P442 certified. FED-STD-209E/Class 1 (ISO 3) Cleanrooms. CSEDO is participating in Declare. |
---|
Lumen Data | CSEDO22 Lumen Data |
---|
Optics | Symmetric optic includes diffused, impact-resistant acrylic lens. |
---|
Patent | U.S. Patent No. 5,902,035. |
---|
Photometrics | Photometry tested to the IESNA LM-79-08 standard. For additional photometric data, please go to www.kenall.com. |
---|
Warranty | Limited five (5) year warranty. |
---|