Controls | Optional LVC and LVCD provides a low-voltage patient interface, controlling the lamp source intensity and optional night light with (LVCD) and without (LVC) dimming control. Separate 0-10V control required for CCT tuning. |
---|
Door Assembly | Roll-formed and butt-welded 6063-T5 extruded aluminum with TGIC polyester powder-coat finish in selected color, with five-stage pre-treatment. Secured to housing with flush-mounted, color-matched and tamper-resistant Torx fasteners. Closed cell silicone gasketing seals doorframe to housing. High-efficiency diffused, impact-resistant acrylic inner lens with outer .250" clear polycarbonate lens. Continuous lens retention with door frame. |
---|
Driver/Controls |
120-277VAC, 50/60Hz electrical input (PF ≥ 0.9, THD < 20%). Minimum 85% electrical efficiency. Serviceable, constant current multi-channel programmable driver with dual analog (0-10V) control inputs for intensity and CCT. Optional DALI (Type 8) driver. Logarithmic intensity profile with 0.1-100% range, with dim-to-dark capabilities. Linear profile on CCT adjustment. Refer to charts on page 2 for further details.
|
---|
Housing | Fabricated 20ga CRS housing with white TGIC polyester powder-coat finish and five-stage pre-treatment. Roll-formed and butt-welded 6063-T5 aluminum extruded collar for door attachment, finished in selected color option using TGIC polyester powder with five-stage pre-treatment. |
---|
Installation |
Suitable for Type-IC recessed ceiling installation into drywall ceilings up to 5/8" thick. External brackets on housing secure luminaire to ceiling structure (mounting hardware by others).
|
---|
LED Module | Serviceable tunable-white, mid-power LED array provides 2700K through 6500K CCT range with a two-point path. Minimum 80 CRI standard (R9 >0) with optional minimum 90 CRI (R9 >50). Optional nightlight in 590nm native amber or 2700K, 80CRI white. |
---|
Listings |
Luminaire is certified to UL standards by Intertek Testing Laboratories for Type-IC and Wet Location installations. IP64 rating per IEC60598. NSF2 Splash/Non-Food Zone rated. Standard CCEA compliance.
|
---|
Photometrics | Photometry tested to the IESNA LM-79-08 standard by an ILAC/ISO17025 accredited laboratory. For detailed photometric information, please visit www.kenall.com. |
---|
Warranty | Limited five (5) year warranty. |
---|